Electric Heated Glass-Lined Reactor
Request a Quote
Technical Parameters of the Glass-Lined Reactor
| Internal Vessel | Jacket | |
| Design Pressure (MPa) | 0.4 | ATM |
| Design Temperature ( ℃ ) | -19 -200 | -19 -200 |
| Symbol | Usage |
| P1-n | Electric Heater Joint |
| Others: a, b, c | Nozzle’s usage is the same that of K type glass-lined reactors of the same specification. |
| Specifications | ||||||||||||
| Nominal Capacity (L) | 50 | 100 | 200 | 300 | 500 | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | |
| Total Capacity (L) | 102 | 180 | 325 | 483 | 743 | 1616 | 2172 | 2640 | 4170 | 5140 | 6470 | |
| Calculated Capacity (Note 1) (L) | 71 | 128 | 247 | 369 | 588 | 1244 | 1714 | 2180 | 3370 | 4334 | 5443 | |
| Jacket Capacity (L) | 84 | 115 | 174 | 218 | 307 | 476 | 300 | 387 | 461 | 774 | 873 | |
| Heat Exchange Area (m²) | 0.53 | 0.85 | 1.26 | 1.75 | 2.64 | 4.55 | 5.76 | 7.23 | 9.33 | 11.85 | 13.74 | |
| Reference Weight (kg) | 446 | 527 | 697 | 966 | 1174 | 1885 | 2280 | 2535 | 3555 | 4055 | 4940 | |
| Dimensions (mm) | d1 | 500 | 600 | 700 | 800 | 900 | 1200 | 1300 | 1300 | 1600 | 1600 | 1750 |
| d2 | 700 | 800 | 900 | 1000 | 1100 | 1400 | 1450 | 1450 | 1750 | 1750 | 1900 | |
| d3 | 986 | 1087 | 1188 | 1288 | 1405 | 1738 | 1915 | 1915 | 2221 | 2221 | 2412 | |
| d6 | 608 | 708 | 810 | 910 | 1010 | 1312 | 1389 | 1389 | 1690 | 1690 | 1840 | |
| h | 1835 | 1980 | 2245 | 2595 | 3035 | 3500 | 3700 | 4050 | 4210 | 4650 | 4820 | |
| h1, h2… | Same as the specs of K type glass-lined reactors | |||||||||||
| Vessel Nozzle DN (mm) | a, b, c, d… | Jacket connecting nozzles referring to the same specs of K type glass-lined reactors | ||||||||||
| Jacket Nozzle DN (mm) | p | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| p1-n | p1-4 | p1-6 | p1-6 | p1-6 | p1-9 | p1-12 | p1-12 | p1-12 | p1-15 | p1-15 | p1-18 | |
| k1, k2… | Nozzles size referring to same specs of K type glass-lined reactors | |||||||||||
| Drive (mm) | DN | 40 | 40 | 50 | 65 | 65 | 80 | 80 | 80 | 95 | 95 | 95 |
| h5 | 980 | 980 | 1250 | 1400 | 1400 | 1580 | 1580 | 1580 | 1680 | 1680 | 1680 | |
| Note 1: Calculated Capacity: Volume under highneck flange. | ||||||||||||