High Temperature / Fire Resistant Cable (Copper Core, Insulated)
HighTemperature/Fire Resistant Cable (Copper Core, Insulated)
Application
This high temperature and fire resistant cable isused for checking signals under high temperature conditions with rated voltageup to 300/500V. It works predominantly as a transmission wire for control andprotect circuits in fire fighting systems and security systems.
ProductStandard
Our high temperature and fire resistant cable is manufactured according to theQ/R-TW6009-2004 standard. The fireproof capability is strictly examined by the GB12666.6-1990 test which is equivalent to the IEC331 test.
Operating Characteristics
1. Operatingtemperature: 200℃ for long-termoperation, 1000℃ for operatingperiod less than 90min.
2. Rated voltageU0/U: 300/500V
3. Minimum ambient temperature: -60℃ for fixed installation, 20℃ for non-fixed installation
4. Bend radius: no less than 10 times the cable outer diameter for non-armoredcable, no less than 12 times the cable outer diameter for armored cable.
Cable Type
Model | Name | Core number | Nominal cross-section area (mm2) |
NHFF | Cu core fire-proof & insulation layer heat-resistance fire-proof cable | 2-37 | 0.5-6 |
NHFPF | Cu core fire-proof&insulation layer heat-resistance shield fire-proof cable |
Note: P Stands for copper wire braided screen; P1 stands for tin-coatedcopper wire braided screen; P2 stands for copper tape screen.
Main Technical Performance
Item | Technical performances | ||||||||||||||
D.C. Resistance of Conductor | 0.5mm2 | 0.75 | 1.0mm2 | 1.5mm2 | 2.5mm2 | 4mm2 | 6mm2 | ||||||||
(Ω/km) at 20℃ | Plated layer | Non-tinplating | Tinplating | Non-tinplating | Tinplating | Non-tinplating | Tinplating | Non-tinplating | Tinplating | Non-tinplating | Tinplating | Non-tinplating | Tinplating | Non-tinplating | Tinplating |
Single strand conductor | 36.0 | 36.7 | 24.5 | 24.8 | 18.1 | 18.2 | 12.1 | 12.2 | 7.41 | 7.56 | 4.61 | 4.70 | 3.08 | 3.11 | |
7strands twisted conductor | 39.0 | 40.1 | 26.0 | 26.7 | 19.5 | 20.0 | 13.3 | 13.7 | 7.98 | 8.21 | 4.95 | 5.09 | 3.30 | 3.39 | |
Test voltage | 2000 V (v/min) | ||||||||||||||
Insulation resistance | ≥300MΩ.km at 20℃ | ||||||||||||||
Fire-proof performance | Grade A(The 3A fuse is not blown under 1000℃ flame condition for 90min) |
Sinceour foundation in 1990, we have aimed to satisfy our global customers byproviding a wide range of products, including rubber sheath flexible cable, welding machineflexible cable, XLPE insulated control cable and XLPEcore prefabricated branch cable, etc.
Please contact us for more product information. We at Huanya are looking forward to cooperating with you and make mutual benefit!