Thermal Bonding Oven

Thermal Bonding Oven
Thermal Bonding Oven
Request a Quote

Thermal bonding oven is used for the thermal treatment of thick fiber web from last process, in order to melt the low melting point fiber in fiber web and increase the tension of fiber web. Non-glue cotton does not contain glue and thus more environmental. Non-glue cotton is also more soft than acupuncture cotton and can be made for thicker cotton products. Thus non-glue cotton is generally used for high end products, such as high end mattress, seat cushion, back cushion, etc. Thermal bonding over for non-glue cotton with natural gas as the heating material is displayed below. We can also offer thermal bonding oven for non-glue cotton with other heating materials like electric heating, coal, steam boiler, etc. So that you can choose most suitable drying oven according to your local energy cost.

Parameters of thermal bonding oven:
Thermal bonding oven for nonwoven production line
Working Width
(mm)
Heating Methods Heating Chambers(mm) Cooling Way Capacity
(kg/h)
M/C Weight
(kg)
2200 By Gas 2000*3 By air 500-800 6000
Conveyor Constituted by Teflon and metal
Motor Brand Made in China
5.5kw *1 Feeding lattice
35.0kw*3 Transfer Fan
0.75kw*3 Up & down ajust motor
Inverter Made in China
Dimension L x W x H Heating Part 6000(L)*4900(W)*3000(H) MM
Cooling Part 2200(L)*4900(W)*3000(H) MM
Complete set machine 12000(L)*4900(W)*3000(H) MM
Gas Connection Heating Medium Natural gas
Maximal heating power by heating up 900kW
Maximal gas flow 90Nm3/h
Average working heating power 25-60% from max
Average gas flow 25-60% from max
Gas pressure before burner 50 - 300mbar
Main gas pipe 1.5
Circulating Fan Installed circulating fans productivity 3 x 60000m3/h
Average circulating air quantity 3 x 40000m3/h
Heating Exhaust Average exhaust air pressure 20 - 200 Pa
Exhaust tube diameter 400mm
Cooling Exhaust Average exhaust air pressure 80 - 400 Pa
Exhaust tube diameter 400mm
Power Connection Voltage 3phase 380V
Frequency 50 Hz
Circulating fans motors max. used power 3x35kW
Other motors installed power 10kW
Total motors power 123kW
Average used motors power 40-70% from max
Electrical supply current level 250A