Application of Ozone Test Chamber The ozone test chamber is intended for testing the anti-aging capacity of rubber and rubber products under an ozone environment. The testing process is in strict compliance with industrial standards, such as JISK6259, ASTM1149, ISO1431, GB/T7762 and GB/T13642.
Technical Parameters of Ozone Test Cabinet
Model
QL-150-40
Nominal volume (L)
262
Parameters
Temperature range
25°C to +65°C
Humidity range
< 60%RH
Temperature fluctuation
±0.5°C
Temperature uniformity
< 2°C
Temperature deviation
±2°C
Humidity uniformity
+2% -3% R.H
Temperature increase/decrease speed
0.7-1.0°C /min
Ozone concentration
50-500PPhm(temperature: 40°C)
Strain rate of fixture
5%-45%(or customized)
Rotational speed of sample holder
1r/min(continuously variable)
Internal size (mm)
W500×H600×D500
Temperature and humidity adjustment method
Balancing method
Environment temperature
5°C to +35°C
Structure
Air outlet and inlet on both sides, along with orderly-arranged sample holders, allowing for stable air flow and high uniformity
Materials
Housing
SECC Double-side galvanized sheet, plastic coated
Internal surface
SUS304/2B stainless steel plates
Insulation
PU foam + fiberglass
Regulator
Heater
Nichrome fin heater
Humidifier
Stainless steel heater, water dish
Fan
Centrifugal fan
Refrigerator
Mechanical compressor
Refrigerant
R404a
Cooling method
Mechanical compression
Controller
Display
7.0 inch, TFT color LCD display
Control method
Touchscreen micro-computer controller, integral windup PID
Auxiliary functions
Malfunction alarm and possible solution, power-off protection, temperature protection, calendar timing, automatic diagnosis
Notes: 1. Nonstandard test chambers can be customized. 2. Above parameters are measured when the ambient temperature is +25℃ and circulating water temperature is +25℃, without sample. 3. The temperature fluctuation is tested in accordance with GB/T5170.2-2008 standard. For GB/T5170.2-1996 standard, the fluctuation is ±0.5℃. 4. The above-mentioned products are designed with a humidifier. 5. The entire test is conducted in accordance with GB/T7762-2003 standards.
Standard
GB/T7762-2003
Rubber, vulcanized or thermoplastic. Resistance to ozone cracking. Static strain test
Simplewell controller
Mitsubishi PLC
Temperature and humidity adjustment range
Optional Configurations 1. Rotary dehumidifier/ polymeric membrane, with a lowest temperature/ humidity content of 5℃/5 %RH. 2. Built-in tempered glass door, easy to move 3. Water purification system, with automatic replenishment function 4. Recorder, save and print testing data 5. Ultrasonic humidifier/ high-pressure spray humidifier, providing continuous high humidity under extreme temperature 6. Dry air blow system, anti-condensation 7. Remote monitoring function, cellphone and computer supportive