Micro Inverter (Grid Tie)
1. The micro inverter works with 36V/72 cell solar panels, Vmp: 35-39V, Vor: 42-46V.
2. An IP65 waterproof design and MC4 connector make the solar inverter suitable for outdoor installation.
3. Built-in communication module supports real-time monitoring.
4. Double AC output connectors are convenient for connecting cables.
5. Circuit design, MPPT technology, and imported industrial components make the grid tie inverter more efficient, more stable in performance, and faster.
6. Parallel modular design (stacking) is convenient for setting, scaling, and configuring systems.
7. The photovoltaic inverter is adaptable to high speed DSP (Digital Signal Processor) and precision sensing IC, which precisely measure various electrical parameters.
Rated Power | 200W | 230W | 250W | 300W |
Matched Solar Panel | Vmp : 35-39V Voc : 42-46V | |||
DC Input Voltage Range | 24-48V | |||
MPPT Voltage | 28V-36VDC | |||
Max. DC Input Power | 10A | 15A | 15A | 15A |
AC Output Voltage Range | 120VAC(90-140VAC) or 230VAC(190-260VAC) | |||
Frequency Range | 50Hz/60Hx | |||
Power Factor | >98.5% | |||
THD | <5% | |||
Phase Shift | <1% | |||
Waterproof Grade | IP65 | |||
Peak Efficiency (110V) | 95% | 95% | 95% | 95% |
Stable Efficiency (110V) | 92% | 91% | 91% | 91% |
Cooling | Nature Cooling | |||
Peak Efficiency (220V) | 95% | 95% | 95% | 95% |
Stable Efficiency (220V) | 93% | 92% | 92% | 92% |
Protection | Islanding ; Short-circuit ; Converse connection ; Low voltage ; Over voltage ; Over temperature; etc | |||
Work Temperature | -25℃ - 65℃. | |||
EMC ( Electro Magnetic Compatibility ) | EN61000-6-3:2007 EN61000-6-1:2007 | |||
Grid Disturbance | EN 50178 EN 62109-1 VDE0126-1-12 | |||
Grid Detection | DIN VDE 1026 U1741 | |||
Certifcate | CE |
1. The micro inverter works with 24V/60 cell solar panels, Vmp: 26-30V, Voc: 34-38V.
2. An IP65 waterproof design and MC4 connector make the solar inverter suitable for outdoor installation.
3. Built-in communication module supports real-time monitoring.
4. Double AC output connectors are convenient for connecting cables.
5. Circuit design, MPPT technology, and imported industrial components make the grid tie inverter more efficient, more stable in performance, and faster.
6. Parallel modular design (stacking) is convenient for setting, scaling, and configuring systems.
7. The photovoltaic inverter is adaptable to high speed DSP (Digital Signal Processor) and precision sensing IC, which precisely measure various electrical parameters.
Rated Power | 200W | 230W | 250W | 300W |
Matched Solar Panel | Vmp : 26-30V Voc : 34-38V | |||
DC Input Voltage Range | 20-40V | |||
MPPT Voltage | 24V-33VDC | |||
Max. DC Input Power | 10A | 15A | 15A | 15A |
AC Output Voltage Range | 120VAC(90-140VAC) or 230VAC(190-260VAC) | |||
Frequency Range | 50Hz/60Hx | |||
Power Factor | >98.5% | |||
THD ( Total Harmonic Distortion ) | <5% | |||
Phase Shift | <1% | |||
Waterproof Grade | Ip65 | |||
Peak Efficiency (110V) | 95% | 95% | 95% | 95% |
Stable Efficiency (110V) | 92% | 91% | 91% | 91% |
Cooling | Nature Cooling | |||
Peak Efficiency (220V) | 95% | 95% | 95% | 95% |
Stable Efficiency (220V) | 93% | 92% | 92% | 92% |
Protection | Islanding ; Short-circuit ; Converse connection ; Low voltage ; Over voltage ; Over temperature; etc | |||
Work Temperature | -25℃ - 65℃ | |||
EMC | EN61000-6-3:2007 EN61000-6-1:2007 | |||
Grid Disturbance | EN 50178 EN 62109-1 VDE0126-1-12 | |||
Grid Detection | DIN VDE 1026 U1741 | |||
Certifcate | CE |
1. The micro inverter works with 18V/36 cell solar panels, Vmp: 18-21V, Voc: 20-24V.
2. Supports low-powered wind turbines using grid power. Wind turbine DC input:24.
3. Uses high-frequency isolation transformer for efficiency and safety.
4. Circuit design, MPPT technology, and imported industrial components make the grid tie inverter more efficient, more stable in performance, and faster.
5. Parallel modular design (stacking) is convenient for setting, scaling, and configuring systems.
Rated Power | 200W | 300W | 400W | 500W | 600W | 800W |
Matched Solar Panel | Vmp : 18 - 21V Voc : 20 - 24V | |||||
DC Input Voltage Range | 10.5 - 28V | |||||
MPPT Voltage | 15-23VDC | |||||
Max. DC Input Power | 20A | 25A | 30A | 35A | 45A | 60A |
AC Output Voltage Range | 120VAC(90-140VAC) or 230VAC(190-260VAC) | |||||
Frequency Range | 50Hz/60Hx | |||||
Power Factor | >97.5% | |||||
THD | <5% | |||||
Phase Shift | <1% | |||||
Waterproof Grade | Indoor design | |||||
Peak Efficiency (110V) | 90% | 90% | 88% | 87% | 85% | 83% |
Stable Efficiency(110V) | 88% | 87% | 86% | 84% | 84% | 81% |
Cooling | Fan | |||||
Peak Efficiency (220V) | 91% | 90% | 88% | 87% | 85% | 85% |
Stable Efficiency (220V) | 89% | 88% | 87% | 85% | 85% | 83% |
Protection | Islanding ; Short-circuit ; Converse connection ; Low voltage ; Over voltage ; Over temperature; etc | |||||
Work Temperature | -25℃ - 65℃ | |||||
EMC | EN61000-6-3:2007 EN61000-6-1:2007 | |||||
Grid Disturbance | EN 50178 EN 62109-1 VDE0126-1-12 | |||||
Grid Detection | DIN VDE 1026 U1741 | |||||
Certifcate | CE |
1.Three input voltage range, suitable for different solar panels:
(1).18V/36 cell solar panels, Vmp is 18-21V and Voc is 20-24V
(2).24V/60 cell solar panels, Vmp is 26-30V and Voc is 34-38V
(3).36V/72 cell solar panels, Vmp is 35-39V and Voc is 42-46V
2. Supports low-powered wind turbine.
3. Uses high-frequency isolation transformer for efficiency and safety.
4. Circuit design, MPPT technology, and imported industrial components make the grid tie inverter more efficient, more stable in performance, and faster.
5. Parallel modular design (stacking) is convenient for setting, scaling, and configuring systems.
Rated Power | 1000W | ||
Matched Solar Panel | Vmp : 18-21V Voc : 20-24V | Vmp : 26-30V,Voc : 34-38V | Vmp : 35-39V,Voc : 42-46V |
DC Input Voltage Range | 10.5-28V | 20-40V | 24-48V |
MPPT Voltage | 15-23VDC | 24-34VDC | 26-36VDC |
Max. DC Input Power | 80A | 60A | 50A |
AC Output Voltage Range | 120VAC(90-140VAC) or 230VAC(190-260VAC) | ||
Frequency Range | 50Hz/60Hx | ||
Power Factor | >97.5% | ||
THD | <5% | ||
Phase Shift | <1% | ||
Waterproof Grade | Indoor design | ||
Peak Efficiency (110V) | 82% | 87% | 87% |
Stable Efficiency (110V) | 79% | 84% | 85% |
Cooling | Fan | ||
Peak Efficiency (220V) | 82% | 87% | 89% |
Stable Efficiency (220V) | 80% | 85% | 85% |
Protection | Islanding ; Short-circuit ; Converse connection ; Low voltage ; Over voltage ; Over temperature; etc | ||
Work Temperature | -25℃-65℃ | ||
EMC | EN61000-6-3:2007 EN61000-6-1:2007 | ||
Grid Disturbance | EN 50178 EN 62109-1 VDE0126-1-12 | ||
Grid Detection | DIN VDE 1026 U1741 | ||
Certifcate | CE |
1. Suitable for 36V/72 cell solar panels, Vmp: 35-39V, Voc:42-46V.
2. 15-60V DC wide input voltage, classification processing for different input voltages from different DC power
supplies.
3. Multi-LED indicators.
4. Uses high-frequency isolation transformer for efficiency and safety.
5. Circuit design, MPPT technology, and imported industrial components make the grid tie inverter more efficient, more stable in performance, and faster.
6. Parallel modular design (stacking) is convenient for setting, scaling, and configuring systems.
Rated Power | 200W | 300W | 400W | 500W | 600W |
Matched Solar Panel | Vmp : 35-39V Voc : 42-46V | ||||
DC Input Voltage Range | 15-60V | ||||
MPPT Voltage | 18-48VDC | ||||
Max. DC Input Power | 15A | 20A | 25A | 30A | 35A |
AC Output Voltage Range | 120VAC(90-140VAC) or 230VAC(190-260VAC) | ||||
Frequency Range | 50Hz/60Hx | ||||
Power Factor | >98.5% | ||||
THD | <5% | ||||
Phase Shift | <1% | ||||
Waterproof Grade | Indoor design | ||||
Peak Efficiency (110V) | 88% | 88% | 86% | 85% | 85% |
Stable Efficiency (110V) | 86% | 86% | 85% | 84% | 83% |
Cooling | Fan | ||||
Peak Efficiency (220V) | 90% | 90% | 88% | 88% | 85% |
Stable Efficiency (220V) | 88% | 88% | 86% | 86% | 84% |
Protection | Islanding ; Short-circuit ; Converse connection ; Low voltage ; Over voltage ; Over temperature; etc | ||||
Work Temperature | -25℃-65℃ | ||||
EMC | EN61000-6-3:2007 EN61000-6-1:2007 | ||||
Grid Disturbance | EN 50178 EN 62109-1 VDE0126-1-12 | ||||
Grid Detection | DIN VDE 1026 U1741 | ||||
Certifcate | CE |