Two Zone Thermal Shock Test Chamber
Application of Thermal Shock Test Chamber
The two-zone thermal shock test chamber is a functional machine for reliability tests of various electronic products, components and materials. It provides high temperature, low temperature, and other types of temperature shocks to test the stability and durability of products.
Model | Temperature range | Dimensions (W×H×D )mm |
TST-11-A | High temperature, +60 to +200℃ | 320×148×230 |
Low temperature, -40 to 0℃ | ||
TST-11-B | High temperature, +60 to +200℃ | 320×148×230 |
Low temperature, -55 to 0℃ | ||
TST-11-D | High temperature, +60 to +200℃ | 320×148×230 |
Low temperature, -65 to 0℃ | ||
TST-45-A | High temperature, +60 to +200℃ | 350×300×308 |
Low temperature, -40 to 0℃ | ||
TST-45-B | High temperature, +60 to +200℃ | 350×300×308 |
Low temperature, -55 to 0℃ | ||
TST-45-D | High temperature, +60 to +200℃ | 350×300×308 |
Low temperature, -65 to 0℃ | ||
TST-132-A | High temperature, +60 to +200℃ | 510×510×510 |
Low temperature, -40 to 0℃ | ||
ST-132-B | High temperature, +60 to +200℃ | 510×510×510 |
Low temperature, -55 to 0℃ | ||
ST-132-D | High temperature, +60 to +200℃ | 510×510×510 |
Low temperature, -65 to 0℃ |
GB/T2423.1-2008 | Environmental Testing - Part 2: Test Methods - Tests A: Cold |
GB/T2423.2-2008 | Environmental Testing - Part 2: Test Methods - Tests B: Dry heat |
GB/T2423.22-2002 | Environmental testing for Electric and Electronic Products--Part 2: Test Methods--Test N: Change of Temperature |
GJB150.3-1986 | Environmental Test Methods for Military Equipment--High Temperature Test |
GJB150.4-1986 | Environmental Test Methods for Military Equipment--Low Temperature Test |
GJB150.5-1986 | Environmental Test Methods for Military Equipment--Temperature Shock Test |
The detection system and detection method has obtained a patent for invention. According to the specific needs for testing, users can control the heating power to realize rapid warming. The temperature difference can also be accurately controlled. TST thermal shock test chamber has the advantages of fast heating rate, small temperature difference and high detection precision.
Optional Configurations
1. Rotary dehumidifier/ polymeric membrane, with a lowest temperature/ humidity content of 5℃/5 %RH.
2. Built-in tempered glass door, easy to move
3. Water purification system, with automatic replenishment function
4. Recorder, save and print testing data
5. Ultrasonic humidifier/ high-pressure spray humidifier, providing continuous high humidity under extreme temperature
6. Dry air blow system, anti-condensation
7. Remote monitoring function, cellphone and computer supportive
Cooling Equipment