Application of Thermal Shock Test Chamber
The three-zone thermal shock test chamber simulates high temperature, low temperature and other environments and is often used in reliability tests for a variety of electronic products, components and materials.

Technical Parameters of Three-Zone Thermal Shock Test Chamber
Model KTS-41A KTS-41B KTS-41D KTS-71A KTS-71B KTS-71C KTS-110A KTS-110B KTS-110D KTS-301A KTS-301B KTS-3011D
Temperature range +60 to +200°C +60 to +200°C +60 to +200°C +60 to +200°C
-40 to +0°C -55 to +0°C -65 to +0°C -40 to +0°C -55 to +0°C -65 to +0°C -40 to +0°C -55 to +0°C -65 to +0°C -40 to +0°C -55 to +0°C -65 to +0°C
Cooling method Air cooling or water cooling
Temperature recovery conditions High temperature + 150℃ 30min
Ambient temperature 5 min
Low temperature -40℃ 30min -55℃ 30min -65℃ 30min -40℃ 30min -55℃ 30min -65℃ 30min -40℃ 30min -55℃ 30min -65℃ 30min -40℃ 30min -55℃ 30min -65℃ 30min
Temperature recovery time -40℃ 30min -55℃ 30min -65℃ 30min -40℃ 30min -55℃ 30min -65℃ 30min -40℃ 30min -55℃ 30min -65℃ 30min -40℃ 30min -55℃ 30min -65℃ 30min
Internal size (mm) W 240 410 650 970
H 460 460 460 460
D 370 370 370 670
External size (mm) W 1300 1300 1500 1500 1720 1720 2050 2050
H 1900 1900 1900 1900 1900 1900 1900 1900
D 1700 1800 1700 1800 1800 1900 2100 2200
Sample weight 2.5KG 5KG 10KG 24KG
Power supply AC380±10% , three-phase four-wire + ground wire, /AC220V /AC110 50Hz / 60HZ
Pressure of compressed air 0.4 to 0.7MPa
Water pressure 0.2 to 0.5MPa
Standards
GB/T2423.1-2008 Environmental Testing - Part 2: Test Methods - Tests A: Cold
GB/T2423.2-2008 Environmental Testing - Part 2: Test Methods - Tests B: Dry heat
GB/T2423.22-2002 Environmental testing for Electric and Electronic Products - Part 2: Test Methods - Test N: Change of Temperature
GJB150.3-1986 Environmental Test Methods for Military Equipment - High Temperature Test
GJB150.4-1986 Environmental Test Methods for Military Equipment - Low Temperature Test
GJB150.5-1986 Environmental Test Methods for Military Equipment - Temperature Shock Test

The detection system and detection method has obtained a patent for invention. According to the specific needs for testing, users can control the heating power to realize rapid warming. The temperature difference can also be accurately controlled. KTS thermal shock test chamber features fast heating rate, small temperature difference and high detection precision.

  • Simplewell controller
  • Mitsubishi PLC
  • Temperature and humidity adjustment range

Optional Configurations
1. Rotary dehumidifier/ polymeric membrane, with a lowest temperature/ humidity content of 5℃/5 %RH.
2. Built-in tempered glass door, easy to move
3. Water purification system, with automatic replenishment function
4. Recorder, save and print testing data
5. Ultrasonic humidifier/ high-pressure spray humidifier, providing continuous high humidity under extreme temperature
6. Dry air blow system, anti-condensation
7. Remote monitoring function, cellphone and computer supportive

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Cooling Equipment

  • TECUMSEH fully hermetic compressor
  • BOCK inverter compressor
  • BITZER semi-hermetic compressor